“Hot-Swapping” RocketPort Serial Hub Si Devices 23
8. Make sure the serial hub is highlighted and click
Properties
. The Device Setup window displays:
9. Enter the network (MAC or IP) address of the replacement RocketPort Serial Hub Si.
Note: Leave all other settings the same. The unit being swapped in must have the same number of ports and
the same COM number configuration as the unit being taken out of service. If you use IP addressing, the
new unit may be configured to use the same IP address as the old one.
10. Click
OK
to exit to the Main Setup window.
11. Click
OK
to exit to the Windows Device Manager.
12. Click
OK
to exit to the Windows System Properties.
13. Click
OK
to exit to the Windows desktop.
The new RocketPort Serial Hub Si immediately replaces the old one under the old hub’s device name.
Note: Restarting the system is not needed, however, the RocketPort Serial Hub Si may need to have the power
turned off and then back on.